large-capacity centrifuge

產(chǎn)品簡(jiǎn)介

SG-852-type large-capacity centrifuge is the company according to the user experience,Carefully design and development of a new generation of centrifuges products

產(chǎn)品型號(hào):SG-852-type
更新時(shí)間:2019-05-05
廠商性質(zhì):生產(chǎn)廠家
訪問(wèn)量:3684
詳細(xì)介紹在線留言

Product Introduction:
SG-852-type large-capacity centrifuge is  the company  according to the user experience,Carefully design and development of a new generation of centrifuges products, and compared to similar products with higher quality advantage:apply to the hospital laboratory, biochemistry laboratory for qualitative analysis, for plasma, serum, urea, and vaccine manufacturing use. is applicable to all types of laboratory samples of high-capacity centrifugal precision laboratory instruments.
Product features:
1, outstanding performance: micro-computer control, frequency control DC, brushless DC motor without carbon powder pollution;
2, simple: touch panel, digital display, intuitive and reliable;
3, high-capacity multi-rotor, the user easily select
Technical data:
Maximum speed: 5000r/min
1 rotor: 4 * 100ml
No. 2 rotor: 8 * 50ml
No. 3 rotor: 28 * 10ml
Motor: Brushless DC Motor
Timing range: 0-99min


Handling Precautions
Work in a high speed centrifuge, used to safety and to ensure that the equipment to maintain high precision work, we must do the following:
1.Centrifuges used to be placed in a smooth, strong on the counter; large-capacity high-speed low-speed centrifuge and refrigerated centrifuge to be placed accordingly on the ground in a solid, level place. Centrifuge work done, the load balancing, weight error as small as possible, otherwise it will cause severe vibration, and shaft damage turned centrifuge.
2.Centrifuge starts, switch knob should be on the low speed position, start and then gradually adjust to the desired value. A work, shall knob again transferred to low-bit work, at high speed block ban on direct start.
3.Rotor in the strict inspection before each use if a foreign body and the dirt hole, in order to maintain balance. Turned around and must be kept dry and clean, do not impact abrasion. Such as accidentally dropped, turned to X-ray film should check that no internal injury can continue to use. Turned after each use with warm water (50 Degrees - 60 Degrees) and neutral detergent immersion cleaning, and finally with distilled or deionized water rinse, soft cloth after drying with hair dryer, wax, dry place.
4.Pull all kinds of tube length, strength and stretch are different, should the need to use, the tube can be made of many different materials, such as polyethylene, cellulose, polycarbonates, polypropylene. Use care to ensure the sample, non-corrosive materials, solvent and gradient centrifuge tube and cap components. Expired, the aging, there are cracks or corrosion of the tube by minimizing or spin-down use. Control the use of plastic tube number, pay attention to standard matching. Centrifugal process may open the centrifuge lid, not by hand or foreign body collisions are turned and the rotation of the centrifuge tube.
5. To ensure safety, be sure to use ground wire
6.In the centrifuge process, such as abnormal phenomena, such as the noise and vibration is not normal, should immediay stop checks, not to find reasons not to continue to operate .
7.Daily use of centrifuges in the process, every three months the level of response to host a degree of correction for each transfer using 500 million deal with a vacuum pump oil, working 500h should check drive motor carbon brush, preferably with a vacuum cleaner to friction toner remove, if necessary, to replace carbon brushes or commutator with fine sandpaper polish。Should be cleaned about every driver using the 1500h site with high-speed bearings and grease shaft and turned rust-proof joint of fat should be kept painted, do not be long-term anti-rust oil coating oil paper wrap. When not in use should be switched each month low 1 or 2 times, each time 0.5h, to ensure the normal operation of the site.
8. Be sure to place the centrifuge tube placed symmetrically, and to keep the weight fairly. Things in the open centrifuge to centrifuge lid.
9. Centrifugal liquid should not be too low boiling point,Should pay attention to internal and external pressure ratio.If it is toxic reagents, but also good ventilation treatment.
 

在線留言

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說(shuō)明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7

掃碼加微信,了解最新動(dòng)態(tài)

掃碼加微信
021-65682142

Copyright © 2025 上海碩光電子科技有限公司版權(quán)所有

技術(shù)支持:化工儀器網(wǎng)    sitemap.xml

滬公網(wǎng)安備 31011002005640號(hào)

人妻日韩中文字幕| 日韩 在线 国产 后入| 亚洲图片综合图区一区| 99久久精品2019| 少妇合集高潮精品| porn cao9| 亚洲精品国产精品乱码不卡√香蕉| 人妻久久精品一区二区电影| 91怕人妻国产| 四区色色色av| 懂色Av区二区三区AV| 亚洲精品五月天婷婷| 国产,操逼,QQ,我,我| 国产情侣自拍小视频| 丰满人妻在公车199| 日韩内射不卡| 色婷婷综合中心| 啪视频在线观看网站| 日欧资源| 亚洲AV高清| 欧亚熟妇色XxXXX| 中文天堂在线无码| 久久高清成人视频| 搜一级黄片视频能看的| 天天操天天美女B| 中午久久久| 8x8ⅹ国产精品一区二区| 亚洲色图自拍偷拍综合一区| 性综合亚洲网| caoporn亚洲在线| 古代级毛片久久麻豆| 中文字幕日韩在线观看视频一区| 国产伦理av免费在线| 老色鬼AV在线| 日本一码二码激情| 亚洲一本久久久久久| 色婷婷视频分类| 三级在线观看一区 麻豆| 最新欧美亚洲色| 欧美黄片天堂| 又长又粗又黄又硬|